CADRO Heater CD-H02,with an overall size of 339mm (length) ×188mm(width) ×200mm(height) (excluding external joint, lifting lug, handle size, etc.),Place the device on the containerrack and activate the cooling system to heat the coolant. When the inlet temperature switch detects the system medium temperature exceeds 30°C, the PTC heater will automatically disconnect and stop heating. If the inlet temperature switch malfunctions, it will not disconnect. When the temperature of the system medium reaches 50℃, the temperature switch on the outlet side of the PTC heater is controlled to disconnect the power supply. The two switches are in series mode to ensure safety.
1) CADRO Heater CD-H02

Figure1-1 CADRO Heater CD-H02 appearance
2) The internal structure of CADRO Heater CD-H02 is shown in the figure below.

Figure1-2 Internal structure of CADRO Heater CD-H02
3) The composition of CADRO Heater CD-H02 is as follows.
Table 1-1 Composition of CADRO Heater CD-H02
| Subsystem | Major parts |
|---|---|
| Liquid supply system | Two 3kW pipeline type PTC heater, temperature switch (25℃ action), temperature switch (50℃action), quick plug connector, pipeline and other related accessories. |
| Power distribution and control system | Airplane socket, knob switch, indicator light, contactor, switch power supply, etc. |
Table 1-2 Working Environment Table
| Name | Index | Remarks |
|---|---|---|
| Operating temperature | -40℃~50℃ | |
| Storage temperature | -40℃~70℃ | |
| Heating medium | Antifreeze/purified water |
| Project | Parameters |
|---|---|
| Input | AC400±5% V,50/60Hz |
| Rated heating | 6 kW |
| Product size | 339mm*188mm*200mm(No protrusion) |
| Weight | ≤12.5 kg |
| Outer tube | 10mm outer diameter |
| Head loss | ≤10 kPa |
| *These can be adapted to customer requirement. | |