• DSC05807
  • DSC05810
  • DSC05811

45ft Integrated Liquid-Cooled Mining Container

The container liquid cooling system is designed to continuously supply the heat-dissipation units of the internal high-hashrate servers with coolant that meets the required pressure, temperature, and flow conditions, ensuring an optimal working environment for the load. The CADRO&DroLinBox HC45 V2 container liquid cooling system adopts forced-air cooling (dry cooler); the internal cooling medium can be selected—based on the local ambient temperature—from antifreeze, deionized water, or pure water.
  • Product Description
  • Product Specifications

System Overview

The container liquid cooling system is designed to continuously supply the heat-dissipation units of the internal high-hashrate servers with coolant meeting the required pressure, temperature, and flow conditions, ensuring a stable and favorable operating environment for the load.

The CADRO&DroLinBox HC45 V2 container liquid cooling system adopts forced-air cooling (dry cooler). Depending on the local ambient temperature, the internal cooling medium can be selected from antifreeze, deionized water, or pure water.

System Composition

Sub-componentFunctionMain Components
Pump StationDelivers and monitors the coolant status to maintain stable system operationCentrifugal pump, expansion tank, sensors, valves, air vents, filters, piping, and other related accessories
Control Cabinet (including main control cabinet and fan control cabinet)Controls the operation of all components in the pump station, reads sensor values and uploads themAir circuit breakers, intermediate relays, PLC, switched-mode power supplies, touch screens, and other related accessories
Network & Power Distribution SystemProvides networking and power distribution for the high-hashrate serversCircuit breakers, aviation connectors, cables, network switches, and other related accessories
Water Distributor AssemblyDistributes and delivers the coolant flowManifolds, elbows, hoses, clamps, valves, and other related accessories
Container-Supplied AccessoriesSupporting components and spare parts required for operating the container liquid cooling systemScrews, micro-switches, aviation plugs, hose clamps, rubber hoses, and related fittings
Dry CoolerTransfers heat from the load to the atmosphereStainless steel heat-exchanger assembly, valves, pressure gauges, and other related accessories

Working Principle

The pump station supplies two streams of coolant that meet the required temperature, pressure, flow, and medium specifications to the water distributor assembly. The distributor delivers the coolant to the server cold plates through two-stage distribution, and the cold plates carry away the heat generated inside the equipment. The heated coolant then enters the dry cooler, where forced-air convection driven by the power fans enables heat exchange between the air and the internal circulating medium. The cooled coolant is once again delivered by the pump station and distributor assembly back to the cold plates. This cycle repeats continuously, constantly removing the heat from inside the heat-generating load, keeping it in thermal equilibrium and maintaining a relatively stable internal temperature so that it always operates in an optimal environment.

Dry Cooler Working Principle:

The dry cooler uses water and air as cooling media. Inside the dry cooler, a series of parallel pipes carry the cooling water, with axial fans mounted on top. During operation, the heat of the flowing water inside the pipes is conducted through the pipe walls to the fins outside, which increase heat-transfer efficiency. The axial fans draw air from the top, enhancing air movement; the air flows between the fins and, through natural draft cooling or fan-forced ventilation, ensures effective contact between the air and the fins. Heat is transferred from the fins to the air, exchanging heat between the higher-temperature coolant coming from the cold plates and the low-temperature air, thereby cooling the liquid inside the pipes. After its temperature drops, the coolant is pumped back into the system by the pump set to dissipate heat once again.

No.ItemSpecificationRemarks
Environmental Indicators
1Operating Temperature-35~40℃Outdoor
Operating Temperature5~40℃Indoor (adjustable fan control extends the controllable temperature range)
2Operating Humidity10%~90%
3Storage Temperature-35~70℃
4Storage Humidity5%~95%
5Altitude≤2000m
Container Technical Specifications
1External Dimensions (L×W×H) (mm)16154×2438×2896
2High-Hashrate Server Capacity196 S21 Hyd. series and S19 Hyd. series high-hashrate servers
3Container CertificationChina Classification Society certified
4Safety CertificationNFPA 79:2021
UL 508A:2018 R8.21 CSA C22.2 No. 14‑18 ANSI/ISO 12100:2012
5Operating Power (kW)1047~1050Excluding dry cooler power consumption
6Dry Cooler Power (kW)43.2
7Input Voltage and Frequency400V±5%
AC,60Hz/50Hz
8Transport Weight (t)19.5Excluding high-hashrate servers and coolant
9Operating Weight (t)24Including high-hashrate servers and coolant
10Main Switch Capacity of Distribution Cabinet (A)1200The container liquid cooling system includes two distribution cabinets, each with one 1200A main switch
11Rated Current (A)≤986Rated current of each distribution cabinet in the container
12Standard Power (kW)1047Excluding dry cooler power consumption
13Maximum Power (kW)1050Excluding dry cooler power consumption
14Rated Current per Server Slot (A)≤10The container liquid cooling system includes two distribution cabinets, each with one 1200A main switch
15Internal InterfaceDN125 (nominal size 139.7‑ISO 2852)
16Flow Rate (m³/h)≥85
Integrated Dry Cooler Technical Specifications
1TypeMicrochannel
2Heat Rejection Capacity (kW)1000
3Outlet Water Temperature @30℃ Ambient35℃±1℃
4Unit CertificationChina Classification Society
5Safety CertificationNFPA 79:2021
UL 508A:2018 R8.21
CSA C22.2 No. 14‑18
ANSI/ISO 12100:2012
6Operating Power (kW)20~32
7Noise @25℃, 15m70dBA