• 40尺板翅式干冷箱-5
  • 40尺板翅式干冷箱-2
  • 40尺板翅式干冷箱-3
  • 40尺板翅式干冷箱-4

40ft Plate-Fin Dry Cooler Container

The microchannel system is designed to continuously provide the cooling fluid with the required pressure, temperature and flow rate for the high computing power server cooling unit to ensure a good working environment for the load.
  • Product Description
  • Product Specifications

System Overview

The microchannel system is designed to continuously provide the cooling fluid with the required pressure, temperature and flow rate for the high computing power server cooling unit to ensure a good working environment for the load.

CD-HC7.5-V1, CD-HC8.5-V1 The microchannel system adopts forced air cooling (microchannel), and the internal cooling medium can be selected according to the local ambient temperature, suchasantifreeze, deionized water or pure water.

System Composition

Table 3-1 Main components of the microchannel system

SubcomponentComponent FeaturesMain components
Control cabinetControl the start and stop of
pumps and fans, and display the
liquid supply temperature, pH
value, and conductivity of the
pipeline system
Circuit breakers, aviation plugs, switches, miniature circuit breakers, intermediate relays, PLCs, switching power supplies, touch screens, and other related accessories
Microchannel
system
Transfer heat from the load to the atmosphereIntegrated water curtain, microchannel heat exchanger, fan, pump, manual exhaust valve, automatic exhaust valve, and other related accessories
Accessories Included
with the Box
Microchannel system accessories
and spare parts required for use
Screws, miniature switches, aviation plugs, clamps, rubber hoses, and related accessories

Working Principle

Microchannel Working Principle: The microchannel system employs water and air as cooling media. Inside the microchannel, parallel pipes contain circulating cooling water, with an axial fan installed at the top. During operation, heat from the circulating water is conducted through the pipe walls to external fins, which enhance thermal efficiency. The axial fan draws air from the top to intensify airflow, allowing air to pass through the fins. Through natural convection or forced ventilation, the air effectively contacts the fins, transferring heat from the fins to the air. This facilitates heat exchange between the high-temperature coolant exiting the water-cooled plateandthe low-temperature air, achieving effective cooling of the liquid inside the pipes. The cooled coolant is then pumped back into the system for further heat dissipation.

40HC/8.5m Dry Tower‑V3
Overall dimensionsTransport dimensions: 12196mm × 2438mm × 2896mm
Working dimensions: 8500mm × 2438mm × 2896mm
Total weight8500kg (8.5T)
Input voltage and frequency360‑440V AC 50/60Hz
Electrical standardCore Electrical Components Passed UL Or CE Certified.
Control SystemPLC, Touch Screen, pH & Conductivity Monitoring, Fan VFD & Alarms, Remote Monitoring, etc.
Heat transfer power1200kW@25℃ ambient temperature
Cooling mediumPure/Soften/Distilled water +Corrosion Inhibitor+Antifreeze(as per requirements)
Dry coolerPlate‑fin
Fan950#*12psc
Single unit air flow32000m³/h
PipeSS304 DN100
Liquid supply temperature(℃)35℃ ±1℃
Sound Pressure LpA (10 m/m)≤55 dB(A)
transportation standardCCS
*The full container of UL and CSA Certified needs to be customized separately.